Sign In | Join Free | My uabig.com
China Shandong Shengtai instrument co.,ltd logo
Shandong Shengtai instrument co.,ltd
Shandong Shengtai instrument co.,ltd
Verified Supplier

6 Years

Home > Petroleum Testing Instruments >

Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC

Shandong Shengtai instrument co.,ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC

  • 1
  • 2

Brand Name : Shandong Shengtai Instrument

Model Number : SD3536

Certification : GB/T3536-2008、GB/T1671-2008

Place of Origin : China

MOQ : 1

Payment Terms : T/T

Supply Ability : 10000 sets/year

Delivery Time : 7-15 work days

Packaging Details : wooden case

Power supply : AC(220±10%)V,50Hz

Heating device : electric furnace heating, no flame, explosion-proof, power 0-600W continuous adjustable

Temperature control : room temperature~400℃, grading 2℃, technical conditions in line with the technical conditions of liquid thermometer used in petroleum products test GB/T514 provisions

Temperature display : LED screen shows temperature parameters. The range is 0ºC~400ºC, accuracy is 0.1ºC

Ignition device : (1) Ignition source: gas (or other civil combustible gas, the same below) (2) Nozzle aperture: 0.6 〜 0.8 mm

Temperature sensor : RTD, PT100

Ambient temperature : (-10~50)ºC

Relative humidity : ≤85%

Maximum power consumption : 650W

Package size : 380mm * 290m * 260mm

Weight : 10kg

Contact Now

SD3536 Semi-automatic Open Flash Point Tester

SD3536 Semi-automatic open flash point tester is in according to the standard of the People's Republic of China GB/T3536-2008 "petroleum products determination of flash point and burning point Cleveland KaiKouBei act the requirements stipulated in the design and manufacture, is suitable for the determination of the fuel oil and oil products outside the mouth flash point is below 79℃, flash point and burning point also support GB/T1671-2008 plasticizer on the determination of flash point.

Semi-automatic Open Flash Point Tester

Semi-Automatic Cleveland Open Cup Flash Point Tester

Semi-Automatic Cleveland Open Cup Flash Point Tester GB/T3536-2008

SD3536Semi-automatic Cleveland Open-Cup Flash Point Tester

Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC

Main technical parameters and indexes

Power supply AC(220±10%)V,50Hz
Heating device electric furnace heating, no flame, explosion-proof, power 0-600W continuous adjustable
Temperature control room temperature~400℃, grading 2℃, technical conditions in line with the technical conditions of liquid thermometer used in petroleum products test GB/T514 provisions
Temperature display LED screen shows temperature parameters. The range is 0ºC~400ºC, accuracy is 0.1ºC
Ignition device

(1) Ignition source: gas (or other civil combustible gas, the same below)

(2) Nozzle aperture: 0.6 〜 0.8 mm

Temperature sensor RTD, PT100
Ambient temperature (-10~50)ºC
Relative humidity ≤85%
Maximum power consumption 650W
Package size: 380mm * 290m * 260mm Weight: 10kg

Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC

Packing List

S/N NAME UNIT Quantity Remarks
1 Open flash point meter set 1
2 Special brass oil cup piece 1
3 Special thermometer piece 1
4 instructions copy 1
5 Certificate of conformity warranty card copy 1

Customers need to provide their own: coal gas source and coal gas source required pressure reducing valve

Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:

----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;

----The materials and main components provided meet the technical requirements specified in the technical documentation;

----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).

----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.

----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.

----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.


Product Tags:

semi automatic open flash point tester

      

220v 50hz open flash point tester

      
Wholesale Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC from china suppliers

Power Ac220±10%V 50hz Semi Automatic Open Flash Point Tester Ambient Temp -10~50ºC Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shandong Shengtai instrument co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)